272-3 Underground Thermal Energy Storage in Mines - Results from an in-situ Field Scale Test
Session: Hydrogeology of Geothermal Resources: From Shallow Systems to Deep Reservoirs
Presenting Author:
Traugott ScheyttAuthors:
Scheytt, Traugott J. 1, Arab, Alireza2, Grab, Thomas3 (1) Chair of Hydrogeology and Hydrochemistry, TU Bergakademie Freiberg, Freiberg, Germany; Freiberg Center for Water Research, TU Bergakademie Freiberg, Freiberg, Germany, (2) Chair of Hydrogeology and Hydrochemistry, TU Bergakademie Freiberg, Freiberg, Germany; Freiberg Center for Water Research, TU Bergakademie Freiberg, Freiberg, Germany, (3) Lehrstuhl für Technische Thermodynamik, TU Bergakademie Freiberg, Freiberg, Germany; Freiberg Center for Water Research, TU Bergakademie Freiberg, Freiberg, Germany,Abstract:
Flooded and partially flooded mine galleries represent a largely untapped class of underground thermal energy storage (Mine Thermal Energy Storage - MTES) reservoirs. This study presents a long-term field demonstration of a fully equipped MTES test-reservoir at the Reiche Zeche underground Research and Teaching mine of TU Bergakademie Freiberg in Germany / Europe. Three controlled heating–cooling cycles with a combined duration of 504 days were carried out and monitored through dense thermometry, tracer testing, and hydrochemical and materials analyses. A total of 38.0 MWh of heat was supplied.
Approximately 90 % of the stored energy resided in the surrounding gneiss, confirming that the rock mass functioned as the principal store while the basin water acted as a rapid carrier and exchanger interface. The rock warmed by 10.1 K at 1.8 m depth after the hottest cycle, consistent with a conduction-dominated regime. Tracer dilution determined a throughflow of 79 L h⁻¹ with a residence time of about 10.5 days, corresponding to an advective heat-loss coefficient of 0.092 kW K⁻¹. Warm phases triggered Fe(II) oxidation and precipitation of Fe-oxyhydroxides that dominated exchanger fouling, while hydrophobic coatings limited conductance losses to roughly 18 %. Integrated field, laboratory, and numerical analyses showed that hydraulic isolation and oxygen control were the main levers for improving efficiency. The results demonstrate reproducible MTES operation under mine conditions and show that advective loss and exchanger fouling govern recoverability. The derived metrics provide a robust basis for MTES design in similar underground settings and highlight the potential of post-mining infrastructure to contribute to the energy storage.
Geological Society of America Abstracts with Programs. Vol. 58, No. 5, 2026
doi: 10.1130/abs/2026AM-18000
© Copyright 2026 The Geological Society of America (GSA), all rights reserved.
Underground Thermal Energy Storage in Mines - Results from an in-situ Field Scale Test
Category
Topical Sessions
Description
Session Format: Oral
Presentation Date: 10/13/2026
Presentation Start Time: 02:10 PM
Presentation Room: CCC, 105
Back to Session